Creative Labs Sound Blaster Audigy 2ZS User Manual

SOUND BLASSTER AUDIGYY 2 ZS and AUDIGY 22 ZS PLATINUM SETUP  
What You Need  
For Audigy 2 ZS Platinum only  
TAD  
CD_IN  
AUX_IN  
SB1394  
CD_SPDIF  
JOYSTICK  
®
Internal FireWire  
AD_EXT cable  
Sound Blaster Audigy 2 ZS  
Platinum Drive  
®
(IEEE 1394) cable  
Sound Blaster Audigy 2 ZS audio card  
Digital CD audio cable  
Joystick/MIDI bracket  
(with ribbon cable)  
Phillips-head screwdriver  
(not included)  
Power splitter cable  
Shunt  
Screws for Platinum Drive  
For Audigy 2 ZS Platinum only  
Preparing Your  
Computer  
Remove metal brackets  
1
Remove any audio card in your  
With Compact Disc Digital Audio (CDDA)  
computer and uninstall its software.  
Disable any on-board audio device  
in your computer.  
Turn off your computer and all  
peripheral devices before removing  
the computer cover.  
extraction enabled on your computer's operating  
system, you do not have to use an audio cable to  
connect your drive to your audio card. For more  
information, refer to the User's Guide (on CD). Go to  
d:\manual\<language>\manual.chm (replace d:\  
with your CD-ROM drive letter and <language> with  
the language that the document is in).  
Remove 5¼" drive  
bay front panel  
RESET  
PCI slot  
Installing Hardware  
For Audigy 2 ZS Platinum only  
2
Connect to system  
power unit  
c
e
a
Connect power  
splitter cable  
Insert Sound  
Blaster Audigy 2 ZS  
T
AD  
CD_  
IN  
audio card  
Platinum Drive  
AU  
X
_IN  
SB1  
39  
4
CD_SP  
DI  
Red stripe  
JP1  
J5  
Attach Joystick/  
Secure  
Platinum  
Drive with  
screws  
provided.  
Connect  
Internal  
FireWire  
(IEEE1394)  
cable  
F
J1  
MIDI bracket  
K
YSTIC  
JO  
_EXT  
D
A
Insert  
Connect  
AD_EXT cable  
Platinum  
Drive into  
drive bay  
Connect Joystick/  
MIDI bracket ribbon  
cable (optional)  
To prevent permanent damage, use only:  
PCI Slot  
- the AD_EXT cable with the AD_EXT connector  
- the Audigy 2 ZS audio card with the Platinum Drive.  
Do not force any cable into a connector. This can cause  
permanent damage to your hardware.  
CD/DVD-ROM drive  
Your Platinum Drive is capable of supporting both dynamic  
and condenser microphones. By default, your Platinum  
Drive is set for use with a condenser microphone. To use a  
dynamic microphone, fit the provided shunt onto Jumper  
JP1 of your Platinum Drive.  
d
f
Connect Internal FireWire  
(IEEE 1394) cable  
TAD  
CD_IN  
AUX_IN  
SB1394  
CD_SPDIF  
Digital CD audio  
cable for digital CD  
audio output  
Red stripe  
Analog CD audio  
cable (available  
separately) for  
analog CD audio  
output  
OR  
Shunt  
JOYSTICK  
SB1394  
CD_SPDIF  
TAD  
CD_IN  
AUX_IN  
SB1394  
JOYSTICK  
Up to two drives can be  
Connect AD_EXT  
cable  
connected simultaneously to  
the Audigy 2 ZS, using both the  
AUX_IN (analog) and CD_SPDIF  
(digital) connectors.  
SB1394  
Audigy 2 ZS  
audio card  
Jumper  
Installing Software  
1. After you have installed your hardware, turn on your computer.  
Windows automatically detects the audio card.  
Useful Information  
Installing Sound Blaster Audigy 2 ZS drivers and applications  
User's Guide (on CD)  
For more information, refer to the User's Guide (on CD).  
Go to Start Programs Creative Sound Blaster Audigy 2 ZSDocumentation →  
Online Manual.  
2. When prompted for the audio drivers, click the Cancel button.  
3
3. Insert the Sound Blaster Audigy 2 ZS Installation and Applications CD into your  
CD-ROM drive. Your CD should start automatically. If it does not, follow the steps  
below:  
Digital output sampling rate  
Make sure you select the sampling rate of the PCM SPDIF output of your Digital Out connector  
to match the requirements of your receiving device. The choices available are 48 kHz or 96 kHz.  
If you do not hear any sound from your digital speakers or experience intermittent hissing,  
you may need to select a lower digital output sampling rate.  
i. Double-click the My Computer icon.  
Alternatively, click Start  
My Computer.  
ii. Right-click the CD-ROM/DVD-ROM drive icon, and then click AutoPlay.  
4. Follow the instructions on the screen to complete the installation.  
5. When prompted, restart your system.  
To select the digital output sampling rate:  
1. In Windows Control Panel, double-click the AudioHQ icon.  
2. In the AudioHQ window, double-click the Device Controls icon.  
3. Click the Sampling Rate tab.  
Uninstalling drivers and applications  
Refer to the Installing Software chapter in the User's Guide (on CD).  
These instructions are applicable to all Windows operating systems.  
4. In the Digital Output Sampling Rate list, click the required sampling rate.  
You can use Creative Diagnostics to test the software and hardware installation.  
Go to Start  
Programs  
Creative  
Sound Blaster Audigy 2 ZS  
Creative Diagnostics.  
PN 03SB000000030 Rev.A  

Elo TouchSystems ENTUITIVE TOUCHMONITOR ET1545C User Manual
Electrolux 922005 User Manual
DCS CP 364GD User Manual
Daewoo CRT Television CN 001M User Manual
Cypress CY8C24223 User Manual
Blodgett SC 10E User Manual
Black Decker Type 1 TRO4070B User Manual
Avaya Definity 6211 User Manual
AT T 9345 User Manual
Asus Computer Hardware GRYPHON Z87 User Manual